HomeProductsFlow regulationAbout Mosbaek North America, Inc.Info & news

» Cyclone flow regulator CY

» Cyclone flow regulator CYD

» Centrifugal flow regulator CEV

» Centrifugal flow regulator CEH

» Double orifice plate DB


 Send a technical inquiry


Functional requirements type CY

The Mosbaek CY flow regulators meet the following functional requirements, which may therefore be specified in invitations for tenders:

 

  • Constantly large orifice opening

 

  • Infinitely adjustable inlet orifice plate with marking for correct setting

 

  • A maximum of 45° change in direction of flow

 

  • Maximum contraction effect in the inlet

 

  • An active bypass in the inlet tube, at orifice openings of less than 4" (~Ø100 mm) for storm water and 6" (~Ø150 mm) for combined system (sewage water)



GeneralTechnical info

Download PDF factsheet

Flexible solution



Application chart

CY flow regulators are designed for capacities from 160 GPM (~10 l/s) up to 9525 GPM (~600 l/s) – see diagram. They are made for submerged or semidry/dry installation. For semidry/dry installation types – please see product descriptions of CYDK, CYDX and CYDV.

 

CY flow regulators for submerged installation may be used for all types of discharge water, i.e. storm water, sewage water or mixed storm and sewage water. Available types are CYE, CYO and CYOE.

 

CYE flow regulators have a patented infinitely adjustable inlet orifice plate, which may be adjusted to ±25% of the capacity in mean position. Actually, this regulator is the only of its kind on the market, whose capacity may be adjusted on site without replacing any components; just loosen two screws with a hexagon socket head wrench and adjust the orifice plate. For a change of capacity, please contact Mosbaek North America, Inc.. We identify the flow regulators by means of its reference number and calculate the setting of the orifice plate to suit the new capacity.

 




CYO regulator with double inlet.

A new type CY flow regulator, designated CYO, has a recently developed safety overflow in the inlet tube (patent pending). The design of the inlet results in an intensified contraction of the inlet jet and, consequently, an increased braking effect. Therefore the CYO model has a mean orifice opening, which is 10-15% larger than that of the conventional Mosbaek CYE flow regulator and even larger compared with certain imitations. The result is a considerable improvement of the reliability. However, the most important advantage is that, even if the larger orifice opening is blocked by an object, the overflow will continue to work and discharge to the relatively low level corresponding to the upper edge of the inlet tube. This active by-pass is the most important conquest within this field for many years.

 

The advantages of the CYE and CYO flow regulators may be combined by ordering type CYOE.

 

Excellent control and large orifice opening


Definition sketch

In general, the CY flow regulators ensure that the flow, Q, is almost constantly equal to the nominal capacity, Qdim, over a large interval of upstream heads. The capacity, Qdim, may be obtained at the top of the ”bump” of the characteristics as well as in the design point. This is illustrated on the characteristic curve of the CY flow regulator.

 

The inlet orifice plate is inclined in relation to the flow direction, which results in a strong contraction of the inlet jet and, consequently, a considerable increase of the braking effect. Thus, a larger orifice opening is obtained.

 


Low construction, operating and maintenance costs


Head-discharge curve for CY

The CY flow regulators are designed for embedment. As the cast banquettes are sloping from all sides towards the bottom race, the build-up of deposits will be minimised as the water is led to the regulator. Also, it is easy to clean the structure by flushing it from the top before descending. Thus, inspection, service and change of capacity may be carried out under the most hygienic conditions. The CY flow regulators may often be installed in existing or planned wells or tanks, as it does not take up much space.

Other features of the CY flow regulators are:

  • Constantly large orifice opening
  • No moving parts
  • No electrical components
  • Made of stainless, acid-resistant steel AISI 316L


 These features contribute to low construction, operating and maintenance costs.

 

Supazote®packing ring for CY


CY with packing ring.

A Supazote® packing ring (patent pending) facilitates dismounting of the flow regulator for modification or replacement by a new larger or smaller, despite the embedment. The Supazote® packing ring may replace the outlet tube, where ø of the outlet is 70% of the diameter of the mounting opening, as a maximum.

 

Typical applications

Generally the CY flow regulator is used in connection with:

  • Outlet from detention basins
  • Overflow structures
  • Pipe storage
  • Capacity limits in hydraulic nodal points
  • Inlets of pumping stations
  • Inlets of separators and waste water treatment plants

 

Besides, this type of regulator may be used in many other situations. Please contact us for further information.

 

For references - please contact Mosbaek North America, Inc.

Mosbaek North America, Inc. • 3525 Piedmont Road • 7 Piedmont Center • Atlanta GA 30305 • E-mail info@mosbaek.com